Measurement range up to 1000V
Applicable for 10W PV modules to 10kW PV system arrays
Failure diagnostic functions built in
Solar irradiance sensor unit is detachable for remote measurements
LCD display, built in keyboard, and diagnostic functions allow stand
alone operation
Extended analysis software package for operation with a PC included
|
MP-170 is a state-of-the-art instrument to measure I-V curve
characteristics to evaluate the performance of PV modules and
systems. Especially designed to measure 10W PV modules to 10kW
PV systems, the MP-170 has a measurement range of up to 1000V
making it well suited for larger voltage PV arrays. It is very
cost effective, compact, portable and includes a solar irradiance
sensor, two temperature sensors, and failure analysis functions.
The Sensor Unit is equipped with a pyranometer with a silicon
detector and comes with a calibration certificate. Solar irradiance
and temperatures can be measured remotely. Coupled with its
internal capabilities to display the differential coefficient
and magnification of the I-V curve, the MP-170 is very effective
for failure diagnosis of the PV array. With a built in keyboard,
LCD, and functional diagnostics, the MP-170 can be operated
without a PC. I-V curves as well as various data such like Voc,
Isc, Pm, STC conversion values, and data for failure diagnosis,
displayed on the LCD, make it very convenient for on-site performance
measurements. A maximum of 300 I-V curves with corresponding
solar and temperature data can be stored in its internal memory.
The MP-170 can also be operated with a PC. The enhanced measurement
and analysis software package for PC operation works with Windows
2000/XP and it has functions of text data saving, graphical
representation, auto continuous measurement, as well as additional
analysis capabilities. |
 |
|
| Specification |
MP-170 |
| Measurement range |
Voltage: 10V - 1000V |
| Current: 1A - 20A |
| Power: 10W - 10kW |
| Data points |
400 points / I-V curve |
| Data storage |
300 IV curves (Internal Memory) |
| Input |
Tester: PV module/array x 1(2 cables to
PV string)
Sensor Unit: Pyranometer or reference cell, Thermocouple x 2
|
| Interface |
USB x 1(PC), RS-485 x 1(Sensor Unit) |
| Measurement parameters |
I-V curve, Pm, Isc, Voc, FF, Ipm, Vpm, Solar
irradiance, Temperature x 2, STC conversion, Differential coefficient
of I-V curve |
| Dimensions |
Tester: W:230mm x L:300mm x H:160mm
Sensor Unit: W:210mm x L:85mm x H:55mm |
| Weight |
Tester: 3.0 kg, Sensor Unit: 0.48 kg, Battery
Box: 0.75 kg |
| Power supply |
Tester: D size battery x 4 or AC adapter
DC9V, 1.3A
Sensor Unit: 006P type battery x 1 (9V) |
| PC Operating system |
Windows 2000/XP |
|
|