FEATURES
High sensitivity transducers
A revolutionary high output Thin Film Heat Flux Transducer and a
type E thermocouple provide accurate readings of the sample's surface
temperature and heat flux.
Advanced electronics
A 24 bit A/D converter and a digital signal processor provide 0.6µV
resolution yielding temperature control and resolution of 0.01°C
Accurate thickness measurement
A sophisticated digital plate position control system with readout
in all four corners of the specimen provides +/-0.025mm accuracy
in thickness measurement.
Precise results
Extensive testing at various locations has shown that HC-074-200
have a repeatability of 0.2%, a reproducibility of 0.5%, and when
the high accuracy calibration mode is used an absolute accuracy
of better than 1%.
Time of tests
The powerful data acquisition system, the low thermal mass solid
state cooling/heating plates and the multistage PID algorithm can
be reached and controlled to 0.01°C in a few minutes. The dual
transducers and advanced electronics provide results for 1" thick
specimens accurate to within 1% of final steady state results in
less than 10 minutes.
Calibration
Two modes are provided. One calibration uses the NIST 1450b standard.
The other employs a special high accuracy NIST traceable calibration
standard accurate to within 0.5%. Calibrations can also be performed
by the user employing their own calibration samples. As many calibrations
as desired can be stored on the PC and sent to the instrument at
any time.
WinTherm Software
Increased flexibility is made available through the software used
under Windows. All the test parameters can be setup and changed
at any time during the test, with the ability to review data in
a variety of formats including graphs. It also provides extensive
automatic data storage on the hard disk.
Automatic Sample Feeder (Option)
The feeder is available on HC-074-200 with the ability to automatically
load and test 21 1" samples. Each sample's results and data are
stored on the PC.

STRUCTURE AND PRINCIPLE
 |
The thermal conductivity of a specimen (Λ) is determined
by the following the equation;
Where QU is the output of the upper heat flux transducer,
QL is the output of the lower heat flux transducer, L is the
thickness of the specimen and ΔT is the temperature
difference between the surfaces of the specimen. The upper
and lower surface temperature of both transducers are provided
on the instrument LCD at the end of the test. In each component
of the conductivity equation, heat flux, thickness of the
specimen and temperature of specimen surfaces, the HC-074
provides extremely precise readings.
|

Line up of HC-074 series
|
model
|
sample size
|
|
|
HC-074-300
|
305 x 305mm, 0 to 51 mm
|
-20 to +95°C
|
|
HC-074-304
|
305 x 305mm, 0 to 102mm
|
-20 to +95°C
Linear Gradient Guard
|
|
HC-074-314
|
-20 to +100°C
|
|
|
|
HC-074-600
|
610 x 610mm, 0 to 203mm
|
-15 to +80°C
|
|
HC-074-630
|
-15 to +80°C
5 transducers
|
|
HC-074-637
|
-15 to +80°C
5 transducers
Soft rubber backing
|
|
|
|
HC-074-800
|
762 x 762mm, 0 to 203mm
|
-15 to +80°C
|
|
HC-074-801
|
-15 to +80°C
|
|
HC-074-807
|
-15 to +80°C
Soft rubber backing
|
|
HC-074-830
|
-15 to +80°C
5 transducers
|
|
HC-074-831
|
-15 to +80°C
5 transducers
|
|
HC-074-837
|
-15 to +80°C
5 transducers
Soft rubber backing
|
|
HC-074-857
|
-15 to +80°C
9 transducers
Soft rubber backing
|
|
|
|
HC-074-1000
|
1041 x 762mm, 0 to 100mm
|
0 to +45°C
|
|
|
|
Automatic Sample Feeder Available for HC-074-200,
300 and 314
|

SPECIFICATION
| Measuring method |
Heat flow method, According to ASTM-C518,
ISO-8301 and JIS A 1412 |
| Thermal conductivity range |
0.005 to 0.8W/m·K |
| Accuracy |
Better than 1% |
| Repeatability |
0.2% |
| Reproducibility |
0.5% |
| Maximum temperature of hot plate |
+75°C |
| Minimum temperature of cold plate |
-20°C |
| Temperature control and resolution |
0.01°C |
| Sample size |
200mm square |
| Sample thickness |
5 to 50mm |
| Actual metering area |
75mm square |
| Standard sample (Supplied) |
EPS (Expanded Poly-Styrene) |
| Interface |
RS-232C |
Dimension, weight (Tester)
(Circulator) |
315 x 470 x 470mm, 16kg
260 x 480 x 630mm, 26.3kg |
Power requirement (Tester)
(Circulator) |
AC115V or 220V, 50/60Hz, 720VA
AC230V 2450VA, AC115V 1650VA |
| Cooling water (by circulator) |
+18°C or lower |
| Software |
Windows (Einglish, 98/NT/2000/XP) Total
control of instrument Two Thickness Test Procedure for improved
accuracy |
|